Siemens Sinamics V20 basic inverters

 
SINAMICS V20 – The cost-effective, reliable and easy-to-use inverter for basic applications

 

      

 

 

Today, in an increasing number of applications in plant and machinery construction, individual automation and drive solutions are demanded that automate simple motion sequences with low associated requirements.

With its compact SINAMICS V20, the basic performance inverter, Siemens offers a simple and cost-effective drive solution for these types of applications. SINAMICS V20 sets itself apart with its quick commissioning times, ease of operation, robustness and cost-efficiency.

 

Minimize your costs

Engineering, commissioning and operating costs as well as those in operation must be kept as low as possible. You have precisely the right answer with our SINAMICS V20. To increase energy efficiency, the inverter is equipped with a control technique to achieve optimum energy efficiency through automatic flux reduction. Not only this, it displays the actual energy consumption and has additional, integrated energy-saving functions. This allows energy consumption to be slashed drastically.

 

Selection and ordering data

Rated power

Rated output currentIrated

Fans

Frame size

SINAMICS V20 
without integrated line filter

SINAMICS V20 
with integrated line filtercategory C2 1)

kW

hp

A

 

 

Article No.

Article No.

230 V 1 AC

0.12

0.16

0.9

FSA

6SL3210-5BB11-2UV0

6SL3210-5BB11-2AV0

0.25

0.33

1.7

FSA

6SL3210-5BB12-5UV0

6SL3210-5BB12-5AV0

0.37

0.5

2.3

FSA

6SL3210-5BB13-7UV0

6SL3210-5BB13-7AV0

0.55

0.75

3.2

FSA

6SL3210-5BB15-5UV0

6SL3210-5BB15-5AV0

0.75

0.75

3.9

FSA

6SL3210-5BB17-5UV0

6SL3210-5BB17-5AV0

0.75

1.0

4.2

1

FSA

6SL3210-5BB18-0UV0

6SL3210-5BB18-0AV0

1.1

1.5

6

1

FSB

6SL3210-5BB21-1UV0

6SL3210-5BB21-1AV0

1.5

2.0

7.8

1

FSB

6SL3210-5BB21-5UV0

6SL3210-5BB21-5AV0

2.2

3.0

11

1

FSC

6SL3210-5BB22-2UV0

6SL3210-5BB22-2AV0

3.0

4.0

13.6

1

FSC

6SL3210-5BB23-0UV0

6SL3210-5BB23-0AV0


1) Shielded motor cable length for FSA max. 10 m and for FSB to FSC max. 25 m. To achieve 25 m shielded motor cable length also with FSA, unfiltered inverters with external line filter have to be used.

Rated power

Rated output currentIrated, 400 V

Rated output currentIrated, 480 V

Fans

Frame size

SINAMICS V20 
without integrated line filter

SINAMICS V20 
with integrated line filter category C3 1)

kW

hp

A

A

 

 

Article No.

Article No.

400 V 3 AC

0.37

0.5

1.3

1.3

FSA

6SL3210-5BE13-7UV0

6SL3210-5BE13-7CV0

0.55

0.75

1.7

1.7

FSA

6SL3210-5BE15-5UV0

6SL3210-5BE15-5CV0

0.75

1.0

2.2

2.2

FSA

6SL3210-5BE17-5UV0

6SL3210-5BE17-5CV0

1.1

1.5

3.1

3.1

1

FSA

6SL3210-5BE21-1UV0

6SL3210-5BE21-1CV0

1.5

2.0

4.1

4.1

1

FSA

6SL3210-5BE21-5UV0

6SL3210-5BE21-5CV0

2.2

3.0

5.6

4.8

1

FSA

6SL3210-5BE22-2UV0

6SL3210-5BE22-2CV0

3.0

4.0

7.3

7.3

1

FSB

6SL3210-5BE23-0UV0

6SL3210-5BE23-0CV0

4.0

5.0

8.8

8.24

1

FSB

6SL3210-5BE24-0UV0

6SL3210-5BE24-0CV0

5.5

7.5

12.5

11

1

FSC

6SL3210-5BE25-5UV0

6SL3210-5BE25-5CV0

7.5

10

16.5

16.5

2

FSD

6SL3210-5BE27-5UV0

6SL3210-5BE27-5CV0

11.0

15

25

21

2

FSD

6SL3210-5BE31-1UV0

6SL3210-5BE31-1CV0

15.0

20

31

31

2

FSD

6SL3210-5BE31-5UV0

6SL3210-5BE31-5CV0


1) Shielded motor cable length for FSA max. 10 m and for FSB to FSD max. 25 m. To reach category C2 or to achieve 25 m shielded motor cable length also with FSA, unfiltered inverters with external line filter have to be used.

 


Benefits;

Easy to install

  • Push-through and wall mounting – side-by-side possible for both
  • Compact installation allows smaller cabinets to be used
  • Push-through mounting allows the cabinet to be cooled more easily
  • Can be run “out-of-the-box” without other options
  • Basic operator actions at a built-in BOP (Basic Operator Panel)
  • One cable to connect SINAMICS V20 with USS and Modbus RTU at terminals
  • Easy integration into existing systems
  • Easy integration into micro automation systems
  • Easier commissioning through standard libraries and connection macros
  • Possible to use dynamic braking to increase braking performance
  • Inverters ≥ 7.5 kW (frame size FSD) have an integrated braking module. In this case, the braking resistor can be directly connected. The dynamic energy is dissipated as heat in a braking resistor with an adjustable duty cycle of between 5 % and 100 %.
 
Easy to use
  • Parameter loading without power supply
  • Parameter settings can be easily transferred from one unit to another using the BOP (Basic Operator Panel) interface module – or even without power supply by using the parameter loader.
  • Less technical support required
  • Short commissioning time

Read more..